The Journal of Allergy and Clinical Immunology
Volume 125, Issue 1 , Pages 32-38 , January 2010

Air filters and air cleaners: Rostrum by the American Academy of Allergy, Asthma & Immunology Indoor Allergen Committee

  • James L. Sublett, MD

      Affiliations

    • Department of Pediatrics, Section of Allergy and Immunology, University of Louisville School of Medicine, Louisville, Ky
    • Family Allergy and Asthma, Louisville, Ky
    • Corresponding Author InformationReprint requests: James L. Sublett, MD, Pediatric Allergy and Immunology, University of Louisville School of Medicine, 9800 Shelbyville Rd, Louisville, KY 40223.
  • ,
  • James Seltzer, MD

      Affiliations

    • Pediatric Environmental Health Specialty Unit, Division of Occupational and Environmental Medicine, University of California, Irvine School of Medicine, Irvine, Calif
  • ,
  • Robert Burkhead, ME

      Affiliations

    • Blue Heaven Technologies, Louisville, Ky
  • ,
  • P. Brock Williams, PhD

      Affiliations

    • Children's Mercy Hospital, Kansas City, Mo
  • ,
  • H. James Wedner, MD

      Affiliations

    • Department of Medicine, Division of Allergy and Immunology, Washington University School of Medicine, St Louis, Mo
  • ,
  • Wanda Phipatanakul, MD, MS

      Affiliations

    • Department of Medicine, Division of Allergy and Immunology, Children's Hospital, Boston, Mass
    • Harvard Medical School, Boston, Mass
  • ,
  • American Academy of Allergy, Asthma & Immunology Indoor Allergen Committee

Received 28 February 2009 ,Revised 11 August 2009 ,Accepted 21 August 2009.

References 

  1. Eggleston PA, Butz A, Rand C, Curtin-Brosnan J, Kanchanaraksa S, Swartz L, et al. Home environmental intervention in inner-city asthma: a randomized controlled clinical trial. Ann Allergy Asthma Immunol. 2005;95:518–524
  2. Tovey ER. Allergen avoidance. Curr Allergy Asthma Rep. 2008;8:126–132
  3. Terreehorst I, Hak E, Oosting AJ, Tempels-Pavlica Z, de Monchy JG, Bruijnzeel-Koomen CA, et al. Evaluation of impermeable covers for bedding in patients with allergic rhinitis. N Engl J Med. 2003;349:237–246
  4. Brandt DM, Levin L, Matsui E, Phiapatanakul W, Smith AM, Bernstein JA, et al. Allergists' attitudes toward environmental control: insights into its current application in clinical practice. J Allergy Clin Immunol. 2008;121:1053–1054
  5. Subbarao P, Dorman SC, Rerecich T, Watson RM, Gauvreau GM, O'Byrne PM. Protection by budesonide and fluticasone on allergen-induced airway responses after discontinuation of therapy. J Allergy Clin Immunol. 2005;115:745–750
  6. Williams PB. Aerodynamic size distribution of endotoxin, cat, dog, and mite allergen in house dust. Ann Allergy Asthma Immunol. 1999;82:115
  7. American Society of Heating. Refrigerating, and Air-Conditioning Engineers. ANSI/ASHRAE standard 52.2-2007—method of testing general ventilation air-cleaning devices for removal efficiency by particle size. Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; 2008;
  8. AHAM.A.o.H.A.M., ANSI/AHAM AC-1-2006: test method for performance of portable household electric room air cleaners. Washington (DC): Association of Home Appliance Manufacturers; 2006;
  9. Zock JP, Jarvis D, Luczynska C, Sunyer J, Burney P. European Community Respiratory Health Survey. Housing characteristics, reported mold exposure, and asthma in the European Community Respiratory Health Survey. J Allergy Clin Immunol. 2002;110:285–292
  10. US Department of Housing and Urban Development. American housing survey for the United States: 2007. Washington (DC): US Department of Housing and Urban Development; 2008;
  11. American Society of Heating. Refrigerating, and Air-Conditioning Engineers. ANSI/ASHRAE 62.2-2007: ventilation and acceptable indoor air quality in low-rise residential building. Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; 2007;
  12. American Lung Association. Furnace filters: tips about your furnace filter. American Lung Association Health House 2008. Available at: http://www.healthhouse.org/. Accessed February 8, 2009.
  13. Gent JF, Triche EW, Holford TR, Belanger K, Bracken MB, Beckett WS, et al. Association of low-level ozone and fine particles with respiratory symptoms in children with asthma. JAMA. 2003;290:1859–1867
  14. Zwemer RJ, Karibo J. Use of laminar control device as adjunct to standard environmental control measures in symptomatic asthmatic children. Ann Allergy. 1973;31:284–290
  15. Villaveces JW, Rosengren H, Evans J. Use of laminar air flow portable filter in asthmatic children. Ann Allergy. 1977;38:400–404
  16. Kooistra JB, Pasch R, Reed CE. The effects of air cleaners on hay fever symptoms in air-conditioned homes. J Allergy Clin Immunol. 1978;61:315–319
  17. Verrall B, Muir DC, Wilson WM, Milner R, Johnston M, Dolovich J. Laminar flow air cleaner bed attachment: a controlled trial. Ann Allergy. 1988;61:117–122
  18. Reisman RE, Mauriello PM, Davis GB, Georgitis JW, DeMasi JM. A double-blind study of the effectiveness of a high-efficiency particulate air (HEPA) filter in the treatment of patients with perennial allergic rhinitis and asthma. J Allergy Clin Immunol. 1990;85:1050–1057
  19. Antonicelli L, Bilo MB, Pucci S, Schou C, Bonifazi F. Efficacy of an air-cleaning device equipped with a high efficiency particulate air filter in house dust mite respiratory allergy. Allergy. 1991;46:594–600
  20. Warburton CJ, Niven RM, Pickering CA, Fletcher AM, Hepworth J, Francis HC. Domiciliary air filtration units, symptoms and lung function in atopic asthmatics. Respir Med. 1994;88:771–776
  21. van der Heide S, Kauffman HF, Dubois AE, de Monchy JG. Allergen reduction measures in houses of allergic asthmatic patients: effects of air-cleaners and allergen-impermeable mattress covers. Eur Respir J. 1997;10:1217–1223
  22. Wood RA, Johnson EF, Van Natta ML, Chen PH, Eggleston PA. A placebo-controlled trial of a HEPA air cleaner in the treatment of cat allergy. Am J Respir Crit Care Med. 1998;158:115–120
  23. Burroughs HK. Improved filtration in residential environments ASHRAE J. 1998;40:47–51
  24. van der Heide S, van Aalderen WM, Kauffman HF, Dubois AE, de Monchy JG. Clinical effects of air cleaners in homes of asthmatic children sensitized to pet allergens. J Allergy Clin Immunol. 1999;104:447–451
  25. Brehler R, Kutting B, Biel K, Luger T. Positive effects of a fresh air filtration system on hay fever symptoms. Int Arch Allergy Immunol. 2003;130:60–65
  26. Morgan WJ, Crain EF, Gruchalla RS, O'Connor GT, Kattan M, Evans R, et al. Results of a home-based environmental intervention among urban children with asthma. N Engl J Med. 2004;351:1068–1080
  27. Morris RJ, Helm TJ, Schmid W, Hacker D. A novel air filtration delivery system improves seasonal allergic rhinitis. Allergy Asthma Proc. 2006;27:63–67
  28. Macintosh DL, Myatt TA, Ludwig JF, Baker BJ, Suh HH, Spengler JD. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems. J Air Waste Manag Assoc. 2008;58:1474–1482
  29. Myatt TA, Minegishi T, Allen JG, Macintosh DL. Control of asthma triggers in indoor air with air cleaners: a modeling analysis. Environ Health. 2008;7:43
  30. Brauner EV, Forchhammer L, Moller P, Barregard L, Gunnarsen L, Afshari A, et al. Indoor particles affect vascular function in the aged: an air filtration-based intervention study. Am J Respir Crit Care Med. 2008;177:419–425
  31. Sulser C, Schulz G, Wagner P, Sommerfeld C, Keil T, Reich A, et al. Can the use of HEPA cleaners in homes of asthmatic children and adolescents sensitized to cat and dog allergens decrease bronchial hyperresponsiveness and allergen contents in solid dust?. Int Arch Allergy Immunol. 2009;148:23–30
  32. Wood RA. Air filtration devices in the control of indoor allergens. Curr Allergy Asthma Rep. 2002;2:397–400
  33. Reisman RE. Do air cleaners make a difference in treating allergic disease in homes?. Ann Allergy Asthma Immunol. 2001;87(suppl 3):41–43
  34. McDonald E, Cook D, Newman T, Griffith L, Cox G, Guyatt G. Effect of air filtration systems on asthma: a systematic review of randomized trials. Chest. 2002;122:1535–1542
  35. Araujo R, Cabral JP, Rodrigues AG. Air filtration systems and restrictive access conditions improve indoor air quality in clinical units: Penicillium as a general indicator of hospital indoor fungal levels. Am J Infect Control. 2008;36:129–134
  36. Barn P, Larson T, Noullett M, Kennedy S, Copes R, Brauer M. Infiltration of forest fire and residential wood smoke: an evaluation of air cleaner effectiveness. J Expo Sci Environ Epidemiol. 2008;18:503–511

 Disclosure of potential conflict of interest: J. L. Sublett is a shareholder in AllergyZone LLC, a speaker for Merck, and a consultant/speaker for GlaxoSmithKline; he has also received research support from Novartis, Merck, GlaxoSmithKline, Capnia, Greer, and Cobalis. J. Seltzer has provided legal consultation or expert witness testimony on the topics of mold, asbestos, carbon monoxide, and benzene. R. Burkhead is the president of Blue Heavens Technologies LLC and has received research support from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). H. J. Wedner has received research support from Genentech and Dyax and has provided legal consultation or expert witness testimony on the topics of mold, formaldehyde, and toxic chemicals. W. Phipatanakul has received research support from the National Institutes of Health. P. B. Williams declares that he has no conflict of interest.

PII: S0091-6749(09)01317-7

doi: 10.1016/j.jaci.2009.08.036

The Journal of Allergy and Clinical Immunology
Volume 125, Issue 1 , Pages 32-38 , January 2010